38 39
Before using this product, make sure that it is entirely suitable for your specific application and
for the environment in which it is used.
Operation of this instrument may cause unacceptable interferences to other electronic equipments,
requiring the user to follow all necessary steps to correct interferences.
Any variation introduced by the user to the supplied equipment may degrade the instrument’s
EMC performance.
To avoid damage or burns, do not put the instrument in microwave ovens. For your own and the
instrument safety do not use or store the instrument in hazardous environments.
HI 710005 Voltage adapter from 115V to 12 Vdc (USA plug)
HI 710006 Voltage adapter from 230V to 12 Vdc (European plug)
HI 710012 Voltage adapter from 240V to 12 Vdc (UK plug)
HI 710013 Voltage adapter from 230V to 12 Vdc (South Africa plug)
HI 710014 Voltage adapter from 230V to 12 Vdc (Australia plug)
HI 731318 Tissue for wiping cuvets (4 pcs)
HI 731331 Glass cuvets (4 pcs)
HI 731335N Caps for cuvets (4 pcs.)
HI 740027P 1.5V AA battery (12 pcs)
HI 740234 Replacement LED for EPA turbidimeter (1 pcs.)
HI 92000 Windows
®
compatible software
HI 920005 5 tag holders with tags
HI 920011 5 to 9 pins RS232 connection cable
HI 93703-50 Cuvets cleaning solution (230 mL)
HI 93703-58 Silicon oil (15 mL)
HI 98713-11 Calibration Kit
ACCESSORIESACCESSORIES
ACCESSORIESACCESSORIES
ACCESSORIES
Hanna Instruments reserves the right to modify the design, construction and appearance of its products
without advance notice.
RECOMMENDATIONS FOR USERSRECOMMENDATIONS FOR USERS
RECOMMENDATIONS FOR USERSRECOMMENDATIONS FOR USERS
RECOMMENDATIONS FOR USERS
ERROR CODESERROR CODES
ERROR CODESERROR CODES
ERROR CODES
HI 98713 has a powerful diagnostic system. The common errors are detected and reported for
easy diagnostic and maintenance.
RORRE NOITPIRCSED NOITCA
;3rrE–1rrE
8rrE;7rrE;6rrE
.srorrelacitirC
.nwodstuhsdnaspeebtnemurtsniehT
ecivresannaHllaC
4rrE
dnaeciwtyltrohsspeebtnemurtsniehT
.sdnoces01retfanwodstuhs
PUylsuoenatlumissserP
ehtteserotNWODdna
.stnetnocMORPEE
PAC .desolctonsidilehT
.dilehtesolC
nruter,stsisreprorreehtfI
.tnemurtsnieht
Lon .thgilonronekorbpmaL
kcehC.pmalehtecalpeR
rofmetsyslacitpoeht
.snoitcurtsbo
oLL .thgilhguonetoN
metsyslacitpoehtkcehC
.snoitcurtsborof
-OL-
tnerrucrofdesudradnatsehT
.wolootsitniopnoitarbilac
dnadradnatsehtkcehC
.enotcerrocehtesu
-IH-
tnerrucrofdesudradnatsehT
.hgihootsitniopnoitarbilac
dnadradnatsehtkcehC
.enotcerrocehtesu
gniknilbgatyrettaB .wolootsiefilyrettabgniniamerehT .seirettabecalpeR
ttAb
rofdegrahcsidooteraseirettabehT
.stnemerusaemtcerroc
.seirettabecalpeR
PC INTERFACEPC INTERFACE
PC INTERFACEPC INTERFACE
PC INTERFACE
To fully use the instrument tag identification system function, the measured data has to be
downloaded to a computer. The instrument can use RS232 or USB connection to communicate
with the PC.
When using the RS232 protocol, simply connect a HI 920011 serial cable between the
instrument and the computer.
To use the USB protocol, simply connect a regular USB cable between instrument and PC.
In both cases, the PC must run the HI 92000 application for successful data transfer.