Hanna-instruments pH 209 Manual de usuario

Busca en linea o descarga Manual de usuario para Instrumentos de medición Hanna-instruments pH 209. Hanna Instruments pH 209 User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - Bench Top pH Meters

Instruction Manualwww.hannainst.compH 209 • pH 209RBench Top pH Meters

Pagina 2 - TABLE OF CONTENTS

1918FC 100BPVDF body, double junction, refillable, combination pH electrode.Use: general purpose for food industry.FC 200BPVDF body, open junction, co

Pagina 3 - SPECIFICATIONS

2120ELECTRODE APPLICATIONREFERENCE GUIDEApplication Electrodes1. Aquarium HI 1332B, HI 1911B2. Bath-water HI 1910B, HI 1130B3. Beer HI 1131B4. Bread H

Pagina 4 - OPERATIONAL GUIDE

2322CE DECLARATION OF CONFORMITYRecommendations for UsersBefore using this product, make sure that it is entirely suitable for the environment in whic

Pagina 5 - PROCEDURE

MANPH209R3 07/05SALES AND TECHNICAL SERVICE CONTACTSAustralia:Tel. (03) 9769.0666 • Fax (03) 9769.0699China:Tel. (10) 88570068 • Fax (10) 88570060E

Pagina 6 - AND MAINTENANCE

32pH 209 bench-top pH meter is designed for simplicity of use.It features a large easy-to-read liquid crystal display (LCD) and userfriendly keyboard.

Pagina 7 - PERIODIC MAINTENANCE

54FUNCTIONAL DESCRIPTIONRange 0.00 to 14.00 pH±1999 mVResolution 0.01 pH / 1 mVAccuracy (@20°C) ±0.01 pH / ±1 mVTypical EMC Deviation ±0.03 pH / ±2 mV

Pagina 8 - FOR HANNA pH SENSITIVE GLASS

764 cm(1½")• Press the pH key to display the pH measurement.• The display shows the pH value of the test solution compensatedfor temperature.If m

Pagina 9 - ORP PRETREATMENT SOLUTIONS

98HI 7004 HI 7007HI 7004IMPORTANTThe instrument's pH range should be re-calibrated:• When the meter is new.• Whenever the pH electrode is replace

Pagina 10 - "S" VERSION

1110ReferenceFilling HoleReferenceFilling HoleSensitiveWireReferenceWireReferenceJunctionGlassBulbGlassBulbReferenceJunctionReferenceJunctionReference

Pagina 11 - REFERENCE GUIDE

1312Follow the Storage Procedure above.CLEANING PROCEDUREGeneral Soak in HI 7061 general cleaning solution for approxi-mately 30 minutes.Removal of fi

Pagina 12 - WARRANTY

1514ACCESSORIESpH CALIBRATION SOLUTIONSHI 70004P pH 4.01 buffer solution, 20 mL sachet, 25 pcsHI 70007P pH 7.01 buffer solution, 20 mL sachet, 25 pcsH

Pagina 13

1716HI 1330BGlass body, semimicro, single junction, refillable, combination pHelectrode. Use: laboratory, vials.HI 1331BGlass body, semimicro, single

Modelos relacionados pH 209R

Comentarios a estos manuales

Sin comentarios