Instruction Manual
HI 9124 HI 9125
Portable Waterproof
pH Meters
www.hannainst.com
28
SALES AND TECHNICAL SERVICE CONTACTS
Australia:
Tel. (03) 9769.0666 • Fax (03) 9769.0699
China:
Tel. (10) 88570068 • Fax (10) 88570060
Egypt:
Tel. & Fax (02) 2758.683
Germany:
Tel. (07851) 9129-0 • Fax (07851) 9129-99
Greece:
Tel. (210) 823.5192 • Fax (210) 884.0210
Indonesia:
Tel. (21) 4584.2941 • Fax (21) 4584.2942
Japan:
Tel. (03) 3258.9565 • Fax (03) 3258.9567
Korea:
Tel. (02) 2278.5147 • Fax (02) 2264.1729
Malaysia:
Tel. (603) 5638.9940 • Fax (603) 5638.9829
Singapore:
Tel. 6296.7118 • Fax 6291.6906
South Africa:
Tel. (011) 615.6076 • Fax (011) 615.8582
Taiwan:
Tel. 886.2.2739.3014 • Fax 886.2.2739.2983
Thailand:
Tel. (662) 619.0708.11 • Fax (662) 619.0061
United Kingdom:
Tel. (01525) 850.855 • Fax (01525) 853.668
USA:
Tel. (401) 765.7500 • Fax (401) 765.7575
For e-mail contacts and a complete list of Sales and
Technical offices, please see www.hannainst.com
.
MAN9125R2
02/08
Vista de pagina 0
1 2 3 4 5 6 ... 13 14

Indice de contenidos

Pagina 1 - HI 9124 HI 9125

1Instruction ManualHI 9124 HI 9125Portable WaterproofpH Meterswww.hannainst.com28SALES AND TECHNICAL SERVICE CONTACTSAustralia:Tel. (03) 9769.0666 • F

Pagina 2

10• The LCD will flash the "WAIT NOT READY" message.• Once the reading is stable, if it is not close to the selected buffer,"WRONG &q

Pagina 3 - ORP ELECTRODES

11• If the reading is not close to the selected buffer, "WRONG "and "WRONG " will blink alternatively;• If the reading is close

Pagina 4 - FUNCTIONAL DESCRIPTION

12The temperature has an effect on pH. The calibration buffer solutionsare affected by temperature changes to a lesser degree than normalsolutions. Du

Pagina 5 - SPECIFICATIONS

13The instrument allows the user to configure several parametersthrough the Setup Menu.To enter the Menu mode, while in measurement mode, press andhol

Pagina 6 - OPERATIONAL GUIDE

14BATTERIESBATTERIESBATTERIESBATTERIESBATTERIESRECHARCHING/REPLACEMENTRECHARCHING/REPLACEMENTRECHARCHING/REPLACEMENTRECHARCHING/REPLACEMENTRECHARCHING

Pagina 7 - ACCESSORIES

2WARRANTYDear Customer,Thank you for choosing a Hanna Instruments product.Please read this instruction manual carefully before using the instruments.T

Pagina 8 - TROUBLESHOOTING GUIDE

3GENERAL DESCRIPTIONThe HI 9124 and HI 9125 are state-of-the-art waterproof, heavy-duty pH meters designed to provide laboratory results and accuracyu

Pagina 9 - Oil/grease

41) Temperature probe socket.2) BNC electrode connector.3) Liquid Crystal Display (LCD).4) RANGE key, to select pH or mV (HI 9125 only).5) ON/OFF

Pagina 10 - then displayed on the

5SPECIFICATIONSSPECIFICATIONSSPECIFICATIONSSPECIFICATIONSSPECIFICATIONSEGNARHp00.61ot00.2-Vm9991±/Vm9.996±)ylno5219IH(C°0.021ot0.02-)F°0.842ot0.4-(NOI

Pagina 11

6INITIAL PREPARATIONThe meter is supplied with rechargeable batteries (located inside themeter - see page 14 for details).To prepare the instrument fo

Pagina 12

7The LCD will show the pH measurement and the temperature of thesample.In order to take more accurate pH measurements, make sure that theinstrument is

Pagina 13 - SETUP MENU

8Submerge the ORP electrode 4cm (1½") into the sample to be testedand wait a few minutes for the reading to stabilize.Measurements within the ±69

Pagina 14

9It is recommended to calibrate the instrument frequently, especially ifhigh accuracy is required.The pH range should be recalibrated:• Whenever the p