Error Alarm 22 mA 3.6 mA Hold Auto- SMS
Config. Relay fault curr. fault curr. mode cleaning sending
22 OFF OFF ON ON ON OFF
23 ON OFF ON ON ON OFF
24 OFF OFF OFF OFF OFF ON
25 ON OFF OFF OFF OFF ON
26 OFF ON OFF OFF OFF ON
27 ON ON OFF OFF OFF ON
28 OFF OFF ON OFF OFF ON
29 ON OFF ON OFF OFF ON
30 OFF OFF OFF ON OFF ON
31 ON OFF OFF ON OFF ON
32 OFF ON OFF ON OFF ON
33 ON ON OFF ON OFF ON
34 OFF OFF ON ON OFF ON
35 ON OFF ON ON OFF ON
36 OFF OFF OFF OFF ON ON
37 ON OFF OFF OFF ON ON
38 OFF ON OFF OFF ON ON
39 ON ON OFF OFF ON ON
40 OFF OFF ON OFF ON ON
41 ON OFF ON OFF ON ON
42 OFF OFF OFF ON ON ON
43 ON OFF OFF ON ON ON
44 OFF ON OFF ON ON ON
45 ON ON OFF ON ON ON
46 OFF OFF ON ON ON ON
47 ON OFF ON ON ON ON
Note that the values in this table are used for error configuration through RS485.
(6) The hold mode is never enabled by the control timing if the “hold time
start” is the same as the “hold time end”. Items C.41 and C.42 apply to all days.
The hold mode can be enabled all day long by using items C.51 to C.57.
(7) See “Temperature Compensation” section for more details about Auto-
matic and Manual temperature compensation functioning.
(8) Whenever the measurement type (G.00) is changed, all conductivity and
(3) When a wrong setup code or value is confirmed, the controller does not
move from the current window, and displays a blinking WRONG message till the
user changes the value. Note that the allowed values for some parameters de-
pend from other settings (e.g. to set a high setpoint to 10.00 mS, first set the
high alarm to a value greater than 10.00 mS).
(4) Each time the controller is powered, the RTC is checked to detect if an RTC
reset occurred since last software initialization. If that happened, the RTC is ini-
tialized with the default date and time (01-01-2000 ; 00:00).
An EEPROM reset does not affect the RTC settings.
(5) The error configuration value is always displayed together with each error
configuration item, and is coded as shown on this table
Error Alarm 22 mA 3.6 mA Hold Auto- SMS
Config. Relay fault curr. fault curr. mode cleaning sending
00 OFF OFF OFF OFF OFF OFF
01 ON OFF OFF OFF OFF OFF
02 OFF ON OFF OFF OFF OFF
03 ON ON OFF OFF OFF OFF
04 OFF OFF ON OFF OFF OFF
05 ON OFF ON OFF OFF OFF
06 OFF OFF OFF ON OFF OFF
07 ON OFF OFF ON OFF OFF
08 OFF ON OFF ON OFF OFF
09 ON ON OFF ON OFF OFF
10 OFF OFF ON ON OFF OFF
11 ON OFF ON ON OFF OFF
12 OFF OFF OFF OFF ON OFF
13 ON OFF OFF OFF ON OFF
14 OFF ON OFF OFF ON OFF
15 ON ON OFF OFF ON OFF
16 OFF OFF ON OFF ON OFF
17 ON OFF ON OFF ON OFF
18 OFF OFF OFF ON ON OFF
19 ON OFF OFF ON ON OFF
20 OFF ON OFF ON ON OFF
21 ON ON OFF ON ON OFF